Calculators
Saved Calculations
0
Projects
mm
inch
Temp-Pressure Relation
Friction Loss Pipes
Friction Loss Fittings
Earth Load
Wheel Load
Adhesive
Expansion Contraction
Velocity
Water Hammer
Support Spacing
Buoyancy
SDR Rating PVC
SDR Rating HDPE
Engineering Calculator
Takween calculator
Choose a calculator and run the check.
Start from the engineering tool library, open the check you need, then save the result when it is ready for review.
Choose tools
Pressure, flow, loading, movement, and rating checks in one workspace.
Run checks
Use focused inputs and quick outputs for common pipe engineering questions.
Save results
Keep calculation results available from the sidebar for export or review.
Project calculator workspace
Projects
Sign in
Register
Use project files for smarter calculations
Keep notes, assumptions, saved results, product matches, and standards evidence together in one calculator workspace.
Drawings, BOQs, datasheets
Saved Calculations
All tools
Calculators
Search calculators
Temp-Pressure Relation
See how temperature changes the working pressure before the pipe is pushed outside its comfort zone.
What you enter
Material, temperature, base pressure
What you get
Derated pressure
Friction Loss Pipes
Turn flow, diameter, and pipe length into a quick head-loss check for pump and network sizing.
What you enter
Length, material, flow, diameter
What you get
Head loss
Friction Loss Fittings
Build a fitting list and convert bends, tees, reducers, and couplers into equivalent pipe length.
What you enter
System, fitting, size, quantity
What you get
Equivalent length
Earth Load
Estimate the soil load sitting on a buried pipe before choosing bedding and trench details.
What you enter
Soil, cover, trench, angle
What you get
Static earth load
Wheel Load
Check how traffic loading transfers through cover depth and reaches the pipe zone.
What you enter
Wheel load, contact, cover
What you get
Traffic load
Adhesive
Estimate adhesive and primer quantities for joint planning, purchase lists, and site preparation.
What you enter
Diameter and joint count
What you get
Required material
Expansion Contraction
Preview pipe movement caused by temperature swing so supports, loops, and joints are planned early.
What you enter
Length, material, temperatures
What you get
Length change
Velocity
Translate flow and internal diameter into velocity, then spot noise, erosion, or sediment risk.
What you enter
Flow and internal diameter
What you get
Water velocity
Water Hammer
Model surge pressure from valve closure so the system is not surprised by sudden pressure spikes.
What you enter
Pipe, material, velocity, closure
What you get
Surge pressure
Support Spacing
Find a practical support interval based on pipe size, wall thickness, temperature, and fluid weight.
What you enter
OD, wall, temperature, fluid
What you get
Max spacing
Buoyancy
Check whether groundwater uplift can float an empty buried pipe before backfill and anchoring are set.
What you enter
Diameter, water height, soil
What you get
Net uplift force
SDR Rating PVC
Convert outside diameter and wall thickness into SDR and an estimated pressure class for PVC systems.
What you enter
OD and wall thickness
What you get
SDR and PN
SDR Rating HDPE
Compare HDPE wall thickness and PE grade against SDR and theoretical pressure rating.
What you enter
OD, wall thickness, PE grade
What you get
SDR and PN
Validation standards
Standards used to validate calculations
Search standards
ISO
International pipe product, material, dimension, pressure, and test conformity.
Evidence
ISO edition, manufacturer certificate, material grade, dimension/class table.
Validation step
Select the exact ISO number and edition before claiming a pass.
ASTM International
Material/product specification, test method, dimension ratio, and manufacturer conformance.
Evidence
ASTM designation, approved submittal, test report, manufacturer table.
Validation step
Verify dimensions, DR/SDR, density, and pressure basis against approved data.
CEN-CENELEC / BSI
European and British-adopted product, installation, pressure, drainage, and testing requirements.
Evidence
EN/BS edition, national annex, authority note, approved material schedule.
Validation step
Match pipe series, class, installation, and testing values to the approved table.
SASO / SABER
Saudi product conformity, national acceptance, and project authority requirements.
Evidence
SASO/SABER record, Saudi project specification, consultant approval, manufacturer certificate.
Validation step
Confirm the Saudi authority requirement for the exact product and use case.
AWWA
Waterworks pressure pipe, distribution, transmission, fittings, and utility acceptance.
Evidence
AWWA edition, utility specification, pressure/DR table, approved product certificate.
Validation step
Use AWWA and manufacturer pressure, surge, joint, and installation data.
NSF/ANSI 61
Health-effects certification for products and materials in contact with drinking water.
Evidence
Certified product listing, potable-water scope, temperature/application rating.
Validation step
Confirm the service is potable water and the product is listed for that application.
NSF/ANSI 14
Plastic piping system component quality, performance, and health-effects certification.
Evidence
NSF/ANSI 14 listing, product marking, normative product specification.
Validation step
Check that pipes, fittings, joining materials, and appurtenances are listed for the intended application.
FM Approvals
Loss-prevention/product approval where the client, insurer, or fire strategy requires FM-approved products.
Evidence
FM approval reference, approved product model, installation scope, fire specification.
Validation step
Use only the exact approved product, size, rating, and installation scope.
UL Standards & Engagement
Electrical conduit/listing and product safety scope, especially rigid PVC conduit and fittings.
Evidence
UL listing, manufacturer datasheet, NEC/code edition, electrical specification.
Validation step
Match conduit type, schedule, marking, and installation scope to the listing.
NEC / NFPA
Electrical conduit fill, pulling, fire/life-safety, and code-driven installation context.
Evidence
NEC/NFPA edition, system scope, entered code table value, authority approval.
Validation step
Use the adopted code edition and project-entered table limits.
IEC
Electrical installation, cable/conduit coordination, and international electrotechnical requirements.
Evidence
IEC or local code edition, electrical specification, entered derating/fill limits.
Validation step
Apply project limits for voltage drop, fill, route temperature, grouping, and derating.
WRAS
UK potable water fittings/material acceptance where the project or authority requires WRAS.
Evidence
WRAS listing/certificate, water-contact service, manufacturer datasheet.
Validation step
Confirm the product is listed for the relevant water-contact scope and temperature.
DVGW
German water/gas product approval and technical rule context where specified.
Evidence
DVGW certificate, service scope, material family, manufacturer datasheet.
Validation step
Use only products certified for the selected service, pressure, and temperature.
Kiwa
Water product testing/certification context used by European and international projects.
Evidence
KIWA certificate/listing, project specification, manufacturer datasheet.
Validation step
Match product listing to material, fluid, pressure/temperature, and installation scope.
ICC / IAPMO (IPC/UPC)
Plumbing code context for fixture units, pipe sizing, drainage, venting, traps, and building plumbing.
Evidence
Code edition, jurisdiction amendments, fixture schedule, authority approval.
Validation step
Use adopted plumbing-code tables and local amendments before final pass/fail.
UAE Codes
UAE municipality, civil defense, utility authority, consultant, and project specification context.
Evidence
Authority profile, consultant approval, project specification, approved supplier record.
Validation step
Select the Emirate/authority and confirm accepted technical standards.
SBC
Saudi Building Code
Saudi building-code and project-code compliance context for applicable building systems.
Evidence
SBC edition/context, project specification, authority approval, accepted standard basis.
Validation step
Confirm whether a building-code clause applies or product standards control the result.